A vulnerability has been found in D-Link DIR-X1860Z up to 1.0.2.220120.165402. Affected is the function routerd.wificfg_get/routerd.get_rand_key of the component ubus JSON-RPC interface. Such manipulation leads to information disclosure. The attack must be carried out from within the local network. Upgrading to version 1.0.7.260821.161908 is able to address this issue. It is suggested to upgrade the affected component. This vulnerability only affects products that are no longer supported by the maintainer.
D-Link DIR-X1860Z ubus JSON-RPC interface routerd.get_rand_key information disclosure
Problem type
Affected products
D-Link
1.0.2.220120.165402 - AFFECTED
1.0.7.260821.161908 - UNAFFECTED
References
https://vuldb.com/vuln/407979
https://vuldb.com/vuln/407979/cti
https://vuldb.com/cve/CVE-2026-94050
https://vuldb.com/submit/949817
https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10513
https://support.dlink.com/resource/SECURITY_ADVISEMENTS/DIR-X1860Z/DIR-X1860Z_REVA_FIRMWARE_V1.0.7.260821.161908_HOTFIX.zip
https://www.dlink.com/
GitHub Security Advisories
GHSA-p6p3-fj5h-8g7w
A vulnerability has been found in D-Link DIR-X1860Z up to 1.0.2.220120.165402. Affected is the...
https://github.com/advisories/GHSA-p6p3-fj5h-8g7wA vulnerability has been found in D-Link DIR-X1860Z up to 1.0.2.220120.165402. Affected is the function routerd.wificfg_get/routerd.get_rand_key of the component ubus JSON-RPC interface. Such manipulation leads to information disclosure. The attack must be carried out from within the local network. Upgrading to version 1.0.7.260821.161908 is able to address this issue. It is suggested to upgrade the affected component. This vulnerability only affects products that are no longer supported by the maintainer.
https://nvd.nist.gov/vuln/detail/CVE-2026-94050
https://support.dlink.com/resource/SECURITY_ADVISEMENTS/DIR-X1860Z/DIR-X1860Z_REVA_FIRMWARE_V1.0.7.260821.161908_HOTFIX.zip
https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10513
https://vuldb.com/cve/CVE-2026-94050
https://vuldb.com/submit/949817
https://vuldb.com/vuln/407979
https://vuldb.com/vuln/407979/cti
https://www.dlink.com
https://github.com/advisories/GHSA-p6p3-fj5h-8g7w
JSON source
https://cveawg.mitre.org/api/cve/CVE-2026-94050Click to expand
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-94050",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"dateUpdated": "2026-09-20T20:00:08.452Z",
"dateReserved": "2026-09-19T21:51:45.934Z",
"datePublished": "2026-09-20T20:00:08.452Z",
"state": "PUBLISHED"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2026-09-20T20:00:08.452Z"
},
"title": "D-Link DIR-X1860Z ubus JSON-RPC interface routerd.get_rand_key information disclosure",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in D-Link DIR-X1860Z up to 1.0.2.220120.165402. Affected is the function routerd.wificfg_get/routerd.get_rand_key of the component ubus JSON-RPC interface. Such manipulation leads to information disclosure. The attack must be carried out from within the local network. Upgrading to version 1.0.7.260821.161908 is able to address this issue. It is suggested to upgrade the affected component. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"affected": [
{
"vendor": "D-Link",
"product": "DIR-X1860Z",
"cpes": [
"cpe:2.3:h:d-link:dir-x1860z:*:*:*:*:*:*:*:*"
],
"modules": [
"ubus JSON-RPC interface"
],
"versions": [
{
"version": "1.0.2.220120.165402",
"status": "affected"
},
{
"version": "1.0.7.260821.161908",
"status": "unaffected"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"description": "Information Disclosure",
"cweId": "CWE-200",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"lang": "en",
"description": "Improper Access Controls",
"cweId": "CWE-284",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://vuldb.com/vuln/407979",
"name": "VDB-407979 | D-Link DIR-X1860Z ubus JSON-RPC interface routerd.get_rand_key information disclosure",
"tags": [
"vdb-entry",
"technical-description"
]
},
{
"url": "https://vuldb.com/vuln/407979/cti",
"name": "VDB-407979 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/cve/CVE-2026-94050",
"name": "CVE-2026-94050 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://vuldb.com/submit/949817",
"name": "Submit #949817 | D-Link DIR-X1860Z 1.0.2.220120.165402 Information Disclosure",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10513",
"tags": [
"related"
]
},
{
"url": "https://support.dlink.com/resource/SECURITY_ADVISEMENTS/DIR-X1860Z/DIR-X1860Z_REVA_FIRMWARE_V1.0.7.260821.161908_HOTFIX.zip",
"tags": [
"patch"
]
},
{
"url": "https://www.dlink.com/",
"tags": [
"product"
]
}
],
"metrics": [
{},
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:X/RL:O/RC:C",
"baseScore": 4.3,
"baseSeverity": "MEDIUM"
}
},
{
"cvssV3_0": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:X/RL:O/RC:C",
"baseScore": 4.3,
"baseSeverity": "MEDIUM"
}
},
{
"cvssV2_0": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N/E:ND/RL:OF/RC:C",
"baseScore": 3.3
}
}
],
"timeline": [
{
"time": "2026-09-19T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2026-09-19T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2026-09-19T23:56:56.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "djzzlim (VulDB User)",
"type": "reporter"
}
],
"tags": [
"unsupported-when-assigned"
]
}
}
}