Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has discovered that validation of incoming XML format request messages is inadequate. This vulnerability could allow an attacker to XSS on the user's browser. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.
PUBLISHED5.2CWE-20
Improper Input Validation
Problem type
Affected products
Hanwha Vision Co., Ltd.
QNV-C8012
Prior to version 2.22.05 - AFFECTED
References
JSON source
https://cveawg.mitre.org/api/cve/CVE-2025-8075Click to expand
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-8075",
"assignerOrgId": "fc9afe74-3f80-4fb7-a313-e6f036a89882",
"assignerShortName": "Hanwha_Vision",
"dateUpdated": "2025-12-26T16:01:16.611Z",
"dateReserved": "2025-07-23T06:07:30.973Z",
"datePublished": "2025-12-26T04:31:38.718Z",
"state": "PUBLISHED"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "fc9afe74-3f80-4fb7-a313-e6f036a89882",
"shortName": "Hanwha_Vision",
"dateUpdated": "2025-12-26T04:31:38.718Z"
},
"title": "Improper Input Validation",
"descriptions": [
{
"lang": "en",
"value": "Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has discovered that validation of incoming XML format request messages is inadequate. This vulnerability could allow an attacker to XSS on the user's browser. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<div><div>Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has discovered that validation of incoming XML format request messages is inadequate. This vulnerability could allow an attacker to XSS on the user's browser. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.</div></div>"
}
]
}
],
"affected": [
{
"vendor": "Hanwha Vision Co., Ltd.",
"product": "QNV-C8012",
"defaultStatus": "unaffected",
"versions": [
{
"version": "Prior to version 2.22.05",
"status": "affected"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"description": "CWE-20 Improper Input Validation",
"cweId": "CWE-20",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://www.hanwhavision.com/wp-content/uploads/2025/12/Camera-Vulnerability-ReportCVE-2025-5259852601-8075.pdf"
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
]
},
"adp": [
{
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-12-26T16:01:16.611Z"
},
"title": "CISA ADP Vulnrichment",
"metrics": [
{}
]
}
]
}
}